Category: Standards & Licensing
IICRC standards, state licensing and certification.
Air Purifier for Asbestos: What HEPA Catches, What OSHA Requires
HEPA traps 99.97% at 0.3 microns, but OSHA and EPA rely on wet methods, negative pressure at 4 air changes an hour and a 70 s/mm2 clearance test, not purifiers.
Stucco Asbestos: Why OSHA Says Stucco Is Not Surfacing Material
Stucco asbestos under federal rules: OSHA’s 1999 letter says stucco is not surfacing material, sprayed ceilings are PACM, and 763.86 needs 3, 5 or 7 samples.
Asbestos Flue Pipe: Spot Transite and Who May Legally Remove It
Asbestos flue pipe on gas water heaters and furnaces: where transite sits, a look and era table, Category II status, NY, WA and MN owner rules, and three published prices.
Does a Home Inspector Check for Asbestos? No: 9 Clauses Quoted
ASHI, InterNACHI and 6 state rules quoted on asbestos, what an inspector still notes, who may sample under EPA, Texas and New York rules, and the option period clock.
Is Vomit a Biohazard? OSHA Says No; Norovirus Rules Say 25 Feet
OSHA’s 1993 letter says vomit without visible blood is not OPIM. The cleanup still runs on norovirus rules: 1,000 to 5,000 ppm bleach, 5 minutes wet, a 25 foot zone.
Is Urine a Biohazard? OSHA’s Visible Blood Rule in 9 Cases
Not under 29 CFR 1910.1030 unless blood is visible. Three OSHA letters, four state rules and nine cases, from sample cups to soaked carpet and ammonia limits.
Asbestos vs Fiberglass: Fiber Width, Lab Proof and Legal Limits
Asbestos fibrils run under 0.01 um wide, glass fibers 1 to 10 um. How PLM tells them apart, where each hides, and why OSHA caps only asbestos at 0.1 f/cc.
Does Asbestos Smell? No: 9 Odors It Gets Blamed For
Asbestos is listed as odorless with a vapor pressure of about 0 mm Hg. Nine odors blamed on it, their real sources and thresholds, and what test settles each.
Asbestos Linoleum: Which Layer Held It and How Labs Read It
Asbestos linoleum is usually felt backed sheet vinyl: which layer held asbestos, how labs report each layer against the 1% line in 40 CFR 61.141, and covering it.
Tear Gas Cleanup: CS vs CN vs Pepper Spray, Room by Room
Tear gas cleanup by agent: CS, CN and pepper spray chemistry from NIOSH and HSDB, why CS dust lasts 5 to 45 days, and what to wash, seal or discard.
Black Mastic Asbestos: Why PLM Misses It and Which Test to Order
Black mastic asbestos explained: federal spec MMM-A-110 eras, why PLM can miss fibres (EPA/600/R-93/116), New York’s TEM rule, and 40 CFR 61.141 status.
Asbestos Duct Tape: Where It Sits, Lab Proof and Ban Status
Asbestos duct tape ran 90 percent asbestos in EPA’s 1985 listing and never got a federal ban date. Where it sits, how PLM confirms it, and Class I rules.